Varian Medical Systems, Inc., headquartered globally in Palo Alto, California, is the world's leading manufacturer of medical devices and software for treating cancer and other medical conditions with radiotherapy, radiosurgery, proton therapy, and brachytherapy. The company supplies informatics ...
Ультразвуковое изображение, на котором появляется основание предстательной железы.
Industry:Medical devices
The process of calibrating each axis to a system-coordinate reference frame. As long as an axis is axis-calibrated, it is unnecessary to perform system calibration a second time. An authorized user, typically a service or manufacturing technician, performs the calibration process as needed. See axis calibration, calibration.
Industry:Medical devices
Системный администратор или sysadmin поддерживает и управляет компьютерной системы или сети. Как правило, имеет все права доступа.
Industry:Medical devices
Хронометраж, который требует координации мероприятий системы в унисон. Также называется sync.
Industry:Medical devices
Аппаратный сигнал формируется стенд каждые 10 мс и направлены в каждый узел, но инспектор, для синхронизации обмена статуса и сообщений между узлами и руководитель. Ранее назывался сердцебиение.
Industry:Medical devices
The maximum difference between the X-ray dose delivered to any two points that are equidistant and symmetrical about the central axis and within the central 80% FWHM (full width at half measure) region, measured at 100 cm TSD (target-to-skin distance) at a depth of 10 cm. This specification applies to the radial and transverse axes of all square field sizes from 10 x 10 cm2 to 40 x 40 cm2.
Industry:Medical devices
The absorbed dose, including that caused by scattering, at the surface of the phantom or the patient's skin surface, usually on the radiation beam axis.
Industry:Medical devices
A metallic object placed in the beam of electrons to produce x-rays. For electron therapy, the target is retracted from the beam. Important note: This is a specific meaning of target, which can be translated freely in contexts as the following: "Used to.
Industry:Medical devices
Центральный встроенный контроллер Clinac. Система функций, выполняемых руководителем являются: • прием команд от рабочих станций и контроля устройств (такие выделенного клавиатуры в консоли комната; рука подвески) и диван боковые панели в процедурный кабинет. • Контроля и мониторинга исполнения плана лечения (луч), координируя движения осей движения с дозой доставка. • Контрольный ручные и автоматические движения осей машины. • Представления статус и положение данных на рабочую станцию. • Реализации безопасности критически важных задач, таких, как получение и обработка ошибок от узлов, тестирование безопасности петли, повышение разломов или утверждая блокировки и остановка движения или лечения при обнаружении потенциально опасной ситуации. Смотрите также SPV.